-40%
Dental Mobile Digital X-Ray Film Machines Unit & X-Ray Film Processor USA
$ 47.51
- Description
- Size Guide
Description
Item DescriptionBLX-8Plus
Product Introduction
This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz
,
and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees
,
located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
Warning: After turning on the machine, wait for 1 minute, the voltage can be stabilized before normal use
;
After each photo taking, you need to wait for the normal value to return before taking a normal photo
。
TECHNICAL SPECIFICATIONS
Tube Voltage
60kV
Tube Current
1mA
Time Exposure
1~~9s
High pressure generator
30kHz DC
Rated Power
60w
Focal Spot To Skin Distance
>20CM
Focus Spot Size
0.3mm(TOSHIBA)
AC110V
~
220V
Supply Frequency
50Hz±1%
Radiation Leakage
<20ugy/h
Battery
24V DC 8000MA
Weight
2KG
Dimensions
25 cm×11..5 cm×17cm (L×W×H)
Reference of the Angles
:
'
Tooth
Upper
Lower
1-2
42
-15
3
45
-18
4-5
30
-10
6-8
28
-5
Reference of the time of exposure
:
Tooth
Adult
Child
Central & Lateral
0.8-1.2
0.8-1.0
Cuspid & 1st Bicuspid
1.2-1.4
1.0- 1.2
Upper 5
,
6
1.6-1.8
1.4-1.6
Upper 7
,
8
3.0-3.5
2.8-3.3.
Lower 5
,
6
1.8-2.0.
1.6-1.8
Lower 7
,
8
2.0-2.5
1.8-2.3
Packing List:
Main machine 1pc
Power line 1pc
User manual 1pc
BLX-5
Features:
1.) The tube voltage frequency of this machine is 30 KHz, and the tube current is 0.2 MA. The radiation
scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead.
2.) Toshiba 0.3mm x 0.3mm micro-focus tube
3.) No protective operation room is needed when installing the complete machine
4.) Flexible adjustment of position and angle of handpiece
5.) Compact in volume, light in weight, convenient for carrying
6.) Time is adjustable, high contrast of picture, imaging in focus
7.) There are vacuum components and high-pressure parts inside of the machine, so for your safety and
the maintenance of the machine
8.) The tube head is equipped with excellent radiation-shield protection (except the radial mouth, and
tests have shown that the radial index is zero. Safety is guaranteed.
9.) Non-film inspection and storage can be realized when corresponding to a sensor
Specifications
Voltage: 110v±10%
Power: 24V 8000MA
Tube current: 0.1mA
Rating: 60W
Frequency: 30 KHz
Exposure time: 1-9 seconds optional
Leak radiation: < 20μgy/h(12lb)
Focus Skin Distance: >20cm
Tube voltage: 60KV
Relative Humidity(RH) < 80%
Storage conditions: 5-40 degrees Celsius, relative Humidity
Net weight: 5.5 kg
Dimension: 47 x 42 x 19 cm
Content:
Main Unit x 1
Dental Film Position x 1
English Manual x 1
Warranty Card x 1
LK-C27
Fetures:
1.This portable dental X-ray unit is high frequency machine.
2.The body is small, light weight and nearly no radiation.
3.It has excellent image quality, portable storage, save more space.
4.It uses high frequency and DC international power supply.
5.All of the components installed in the central PC board concentrated. Shock,set-up, electron tubes, all of them are insulation vacuum, sealed stereotype protection.
6.There are also manual buttons installed on the surface of shell, as well as batteries and charges7.This unit mainly suitable for oral pre-treatment for learning internal organizational structure, root depth and so on, is indispensable in daily life clinic equipment, especially for dental implant surgery.
8. It also can connect with sensor, is great convenience.
9. The battery is durable, it can take about 5 hundred images after fully charged.
10. It can be connected with intra-oral digital X-ray imaging system.
Warning: After turning on the machine, wait for 1 minute, the voltage can be stabilized before normal use
;
After each photo taking, you need to wait for the normal value to return before taking a normal photo
。
Technical Parameter:
Tube voltage: 60KV
Tube current: 1mA
Exposure time: 0.1--2.0s
Frequency: 30KHz
Rate power: 60VA
Distance from skin to cone: 130mm
Tube focus: 0.3mm*0.3mm
Battery: DC14.8V 6400mAh
Output voltage: DC16.8V
Ambient temperature: 5
℃
~40
℃
Relative temperature: <75%RH
Net weight: 2.5KG
Gross weight: 3.5KG
Size(mm): 138*165*185
Package size(mm): 220*240*275
Packing List:
Main body 1pc
User manual 1pc
Operation of the Main Unit
1. Upon receiving, open the box and check the product for possible damage during shipping.
2. Make sure the fittings on the encasement list are packaged within the box.
3. Connect the six-core cable (of the Main Unit) to the joint of the ball head and tighten the screw
4. After the Main Unit and ball head are perfectly fit together, in the international standard
electrical source, grounding is strongly recommended.
5. Turn on the Power; the pilot lamp will be light up.During this time, the digital tube of the main unit
will show the fore setting time. Now the equipment is in standby mode.
6. Setting the time (Skip to next step if unneeded) Use the "SET", "+", and" -" buttons to reset the time
as follows: press SET, the pilot lamp above is illuminated, the machine is now in the time setting
mode→then press "+" and" -" to set the time needed (time range is 0.5-9seconds); press set again when
the time is adjusted the light lamp is off. The equipment is now in standby mode.
7. Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the tooth)
8. Keep the ball head plumb to the tooth projection position; Have the ball head, tooth, and tooth film steadily mutually plumb.
9. After positioning, use theEXP on the main Unit, the remote controller, or the button on the touch head tube to take pictures. The three methods have the same effect. (Notice: gently press)
10. After exposure to the tube, release the start button again (available in three ways) in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray, so the dental films can be used again).
Repeat step 6 to reset the picturing time.To repeat the picturing process, please repeat steps 7 to 9.
11. Turn the power of the main unit off when the work is finished, press POWER, making sure the pilot
lamp is off. Don't keep the main unit long in standby mode.
Points for Attention
1.
Make sure the angle of film, tooth, and b
all head are properly aligned when taking a picture. Keep them steady until the last step of picturing;
making sure that there is no change in any of their positions.
2.
Remember to turn the power offwhen work is done.
3.
Change the battery if the remote controller loses its functioning or if the remote's distance is shorted.
4.
After turning the power on, wait one minute before taking pictures, this allows the ray to provide a
steady output.
5.
The equipment switches into protection mode automatically when the voltage is incorrect. If this
occurs, it will not be able to carry out the normal work of filming.
6.
When taking pictures, the EXP button could stop the objection and then the machine goes back to the
preparation mode.
7.
Use high quality tooth film and developing liquid to make clear pictures.
8.
Handle the ball head gently while in use, so as not to damage the delicate component.
9.
Do not pull hard on the cable which connects the ball head to the main unit.
10.
The cable connecting the ball head to the main unit cannot bear the weight of the ball head, so do not raise the ball head by holding the cable, it will cause damage.
11.
We usually set the time between 3-8 seconds when taking pictures, but the actual time of ray output
is 0.2-0.5 seconds.
12.
If a situation occurs, preventing the machine from taking regular pictures, contact the seller to solve the problem instead of trying to service the product yourself.
13.
Keep the tooth film and the liquid in a proper place and use them within the shelf-life period. While, because the liquid is not allowed to ship by carrier normal, so we take it out before ship, look forward to your understanding.
14.
Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
15.
Other requests accordance with the scope of the technical parameters.
16.
Please read the manual carefully before using.
X-Ray Film Holder
Description:
Applied for traditional or smaller dental films and wireless imaging plates (digital sensor).
During taking picture, it’s better to put the film in the exactly position for making the ill tooth image displayed in the middle of the film.
Reduces Patient's Oral Discomfort and Allows for Better Accuracy and Ease of X-ray Taking Procedure.
Specifications:
Material: plastics
Excellent Sensor Protection
Dental X-ray sensor positioner
For digital sensor with line
the clamp size can be adjusted for different imaging plates
Satisfaction Guaranteed!
Package:
1, (Green) For right maxillary upper premolar/molar and left mandibular
2, (Blue) For left maxillary premolar and right mandibular premolar/molar
3, (Yellow) For maxillary/ mandbular incisor -Anterior teeth
4.( 2pcs small green accessories)Special for smaller sensor, like the introduction book show.
One suit includes 3 Pcs
(
Left, Right, Upper
)
300 Barrier Envelopes SIZE #2
For use Imaging Plate (Digital Sensor), it is used to protect the IP and avoid cross inflection among the doctors and patients .
300 Barrier Envelopes SIZE #2 for Intra Oral X-Ray ScanX Phosphor Storage Plates
Feature:
1.Reduce Cross-Infection.
2.Keep the Phosphor Storage Plate Clean.
3.Easy to use.
4.Low cost, Disposable Use.
5.Compatible with Scan-X Air Techniques and many other brands!
X-Ray Film Processor
Features:
1. It is use view of the dental film processing design ,can wash 30*40mm single film.
2. The machine is small size ,can be directly placed on the table ,Reliable performance, simple operation ,convenient maintenance.
3. Opreating in the daily light can obtain the best dental image all the same
4. The main components of this product for plastic products, with excellent corrosion resistance and strength ,qualitative light easy to move ,can be used in any solid table.
Technical :
Use for film size:30*40mm
The biggest irrigation width:50mm
Medicine tank capacity: enhancement of 250ml,fixing 250ml,250ml water
Washing method: manual
Developing temperature: room temperature
Material: engineering plastic
Net weight:1.5KG
Products size:360*280*310mm
Note:
1)
The film exposure and development time is too long, all can make the film image density is too high, film black. Too little time to film image density is low ,with lighter film.
2)
The film should be uniform in potions cup stir, to ensure that the wash effect.
3)
Time limit, potions have certain times and after each use should cover the lid of the medicine cup, depending on the manufacture`s instructions.
4)
if have a potion fell into eyes, rinse with plenty of water immediately.
Packing list:
Main machine : one set
Three potion 250ML cup
FDA Statement
The sale of this item may be subject to regulation by the U.S.
Food and Drug Administration and state and local regulatory agencies.
If so, you can bid on this item only if you are an authorized purchaser.
If the item is subject to FDA regulation,
I will verify your status as an authorized purchaser of this item before shipping of the item.
Seller name:2Byoung2016
City,State:SHENZHEN,China
Telephone number:0755-15236254
Customer Service
Welcome to our store! We are a professional foreign company selling all kinds of dental equipments.
We have a very professional customer service team.
We will try our best to solve problems for you. Better customer experience and satisfaction is our aim.
From 9:00 to 17:30(Beijing time) on Mondays to Fridays
.
Shipping
The goods you odered will be posted out in the second working day after the paymet has been
made.(We will inform you via email if any delay occured due to holiday events.
General shipping time is between 7-12 working days. (After the shipping started, the order
will be monitored and the track of the item will be posted on paypal.
Destination
Delivery Time
Working Days
7-10
10-15
15-25
25-40
>50
US
Item arrived
80%
10%
8%
1%
Refund
ASIA
Item arrived
30%
40%
20%
10%
Refund
EU
Item arrived
20%
20%
50%
10%
Refund
AU
Item arrived
30%
30%
20%
20%
Refund
Other countries
Item arrived
5%
10%
10%
60%
--
Payment
We accept PayPal onl
y
.
The address in your paypal details will be used as the actual shipping
address, please make sure the address is correct. If you are planning on
combining your items,
please make sure that you wait until ALL
auctions have ended before you visit the checkout. All items must be
paid within 7 days.
Returns
If the item you received is damaged or defective,Please contact us immidately.We will free exchange or refund.
We will pay the return shipping costs if the product is defective or the return is a result of our error. If the item is returned for any other reason you are responsible for the return shipping charges.
You can return your purchase for up to 15 days from the date of delivery. No refund will be issued if the product shows signs of use. Returned package must be in theoriginal packaging, everything must be in new condition, No missing parts.
Our guarantee does not cover accidental damage or wear of product caused by customer.Thank you very much for your understanding!
Contact Us
We're one of the largest online dental suppliers based on many qualified manufacturers in china.If you contact us immediately after placing the order, we will make every effort to assist you with your change request.
Unfortunately, we can not make changes or cancel an order once it has shipped. Any help,need or questions, please do not hesitate to contact us. Looking forward to our friendly & win-win cooperation!
Feedback
You feedback is VERY important to us.Please leave us positive feedback, an positive feedback will be automatically left for you once we receive your full payment.
Please leave us with any concerns prior to leave negative feedback, as we can only correct issues when we are aware of them. We understand the concerns and frustrations you might have, and will try our best to resolve the issues.