-40%
Dental X-Ray Machine/XRay Film Processor Developer Darkroom/X-ray Sensor Digital
$ 47.51
- Description
- Size Guide
Description
STATEMENT :The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. So you can bid it on this item, only if you are an authorized purchaser. If the item is subject to FDA regulation, we have to verify your status as an authorized purchaser of this item before shipping of the item. Thanks for your understanding.
BLX-5
Features:
1.) The tube voltage frequency of this machine is 30 KHz, and the tube current is 0.2 MA. The radiation scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead.
2.) Toshiba 0.3mm x 0.3mm micro-focus tube.
3.) No protective operation room is needed when installing the complete machine.
4.) Flexible adjustment of position and angle of handpiece.
5.) Compact in volume, light in weight, convenient for carrying.
6.) Time is adjustable, high contrast of picture, imaging in focus.
7.) There are vacuum components and high-pressure parts inside of the machine, so for your safety and the maintenance of the machine.
8.) The tube head is equipped with excellent radiation-shield protection (except the radial mouth, and tests have shown that the radial index is zero. Safety is guaranteed.
9.) Non-film inspection and storage can be realized when corresponding to a sensor.
Specifications:
Voltage: 110v±10% and 220V±10%
Power: 24V 8000MA
Charger: 220V/110V, 50Hz.
Tube Current: 0.1mA
Rating: 60W
Frequency: 30 KHz
Exposure Time: 1-9 seconds optional
Leak Radiation: < 20μgy/h (12lb)
Focus Skin Distance: >20cm
Tube Voltage: 60KV
Relative Humidity(RH) < 80%
Storage Conditions: 5-40 degrees celsius, relative humidity.
Net Weight: 5.5 kg
Dimension: 47 * 42 * 19 cm
Content:
Main Unit x 1
Dental Film Position x 1
Charger x 1
English Manual x 1
Warranty Card x 1
Operation of the Main Unit:
1. Upon receiving, open the box and check the product for possible damage during shipping.
2. Make sure the fittings on the encasement list are packaged within the box.
BLX-5(8PLUS)
Product introduction:
This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz
,
and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees
,
located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
Warning:
After turning on the machine, wait for 1 minute, the voltage can be stabilized before normal use
;
After each photo, you have to wait 30 seconds before you can take a normal photo
TECHNICAL SPECIFICATIONS
:
Tube Voltage
60kV
Tube Current
1mA
Time Exposure
1~~9s
High pressure generator
30kHz DC
Rated Power
60w
Focal Spot To Skin Distance
>20CM
Focus Spot Size
0.3mm(TOSHIBA)
Charger Input Voltage
AC110V
~
220V
Supply Frequency
50Hz±1%
Radiation Leakage
<20ugy/h
Battery
24V DC 8000MA
Weight
4.3KG
Dimensions
37 cm×31 cm×28cm (L×W×H)
Reference of the Angles
:
'
Tooth
Upper
Lower
1-2
42
-15
3
45
-18
4-5
30
-10
6-8
28
-5
Reference of the time of exposure
:
Tooth
Adult
Child
Central & Lateral
0.8-1.2
0.8-1.0
Cuspid & 1st Bicuspid
1.2-1.4
1.0- 1.2
Upper 5
,
6
1.6-1.8
1.4-1.6
Upper 7
,
8
3.0-3.5
2.8-3.3.
Lower 5
,
6
1.8-2.0.
1.6-1.8
Lower 7
,
8
2.0-2.5
1.8-2.3
Packing List:
Main machine 1pcs
Power line 1pcs
User manual 1pcs
LK-C27
Fetures:
1.This portable dental X-ray unit is high frequency machine.
2.The body is small, light weight and nearly no radiation.
3.It has excellent image quality, portable storage, save more space.
4.It uses high frequency and DC international power supply.
5.All of the components installed in the central PC board concentrated. Shock,set-up, electron tubes, all of them are insulation vacuum, sealed stereotype protection.
6.There are also manual buttons installed on the surface of shell, as well as batteries and charges7.This unit mainly suitable for oral pre-treatment for learning internal organizational structure, root depth and so on, is indispensable in daily life clinic equipment, especially for dental implant surgery.
8. It also can connect with sensor, is great convenience.
9. The battery is durable, it can take about 5 hundred images after fully charged.
10. It can be connected with intra-oral digital X-ray imaging system.
Warning:
After turning on the machine, wait for 1 minute, the voltage can be stabilized before normal use
;
After each photo taking, you need to wait for the normal value to return before taking a normal photo.
Technical Parameter:
Tube voltage: 60KV
Tube current: 1mA
Exposure time: 0.1--2.0s
Frequency: 30KHz
Rate power: 60VA
Distance from skin to cone: 130mm
Tube focus: 0.3mm*0.3mm
Battery: DC14.8V 6400mAh
Charger input voltage: AC100V-240V±10%
Output voltage: DC16.8V
Ambient temperature: 5
℃
~40
℃
Relative temperature: <75%RH
Net weight: 2.5KG
Gross weight: 3.5KG
Size(mm): 138*165*185
Package size(mm): 220*240*275
Packing List:
Main body 1pc
Charger 1pc
User manual 1pc
X-Ray Film Processor Developer
Features:
1. It is use view of the dental film processing design ,can wash 30*40mm single film.
2. The machine is small size ,can be directly placed on the table ,Reliable performance, simple operation ,convenient maintenance.
3. Opreating in the daily light can obtain the best dental image all the same
4. The main components of this product for plastic products, with excellent corrosion resistance and strength ,qualitative light easy to move ,can be used in any solid table.
Technical :
Use for film size:30*40mm
The biggest irrigation width:50mm
Medicine tank capacity: enhancement of 250ml,fixing 250ml,250ml water
Washing method: manual
Developing temperature: room temperature
Material: engineering plastic
Net weight:1.5KG
Products size:360*280*310mm
Note:
1)
The film exposure and development time is too long, all can make the film image density is too high, film black. Too little time to film image density is low ,with lighter film.
2)
The film should be uniform in potions cup stir, to ensure that the wash effect.
3)
Time limit, potions have certain times and after each use should cover the lid of the medicine cup, depending on the manufacture`s instructions.
4)
if have a potion fell into eyes, rinse with plenty of water immediately.
Packing list:
Main machine : one set
Three potion 250ML cup
X-ray Digital RVG Sensor
Features:
The product is mainly composed of a sensor, an adaptor, a USB connection cable and workstation software. Working together with an X-ray equipment, the Product is intended to make X-ray radiography in dental clinics or veterinary clinics,Sensor size Suitable for child(adult single tooth)and pets.
Hardware Requirements:
Central Processor: Intel Core i3 or higher
Internal Memory: 4GB or higher
Hard Disk: 80GB or higher
Display: 1280X1024
USB interface: two
Keyboard: One
Mouse: One
Software Requirement
Operating Software:Windows 7 SP1,8,10 32/64bit
Runtime: .Net Framework 4.6 or higher, VC++ 2015
Specification:
Product Name: Image RVG x-ray Sensor
Product Model:XVS2121
Operating Voltage:5VDC
Input power:500mW
Spatial Resolution:≥7Lp/mm
Low contrast resolution :Able to display holes with 1mm, 1.5mm, 2mm and
2.5mm diameter on the 0.5mm-thick aluminium foil
Image uniformity ≤2%
Effective image area: 20.16*20.16mm
Sensor Size:26.5mm×32mm×11.7mm
Adaptor Size:60mm×40mm×29.2mm
Total Cable Length: 3 m (sensor cable + control box cable to PC)
Warranty:1 Year
Accessory :
Digital sensor: 1 Set
USB cable :1 PCS
U Disk: 1PCS
Disposable protective sheath: 1 Box(500)
silicon loop: 1 PCS
Sensor holder: 1 PCS
Aluminum plate:1 PCS (40*40*6mm)
FDA:
Device Classification Name
System, X-Ray, Mobile
510(K) Number
K200976
Device Name
SR-8230, SR-8230S Portable X-Ray Unit
Regulation Number
892.172
Classification Product Code
IZL
Date Received
4/13/2020
Decision Date
6/10/2020
Decision
Substantially Equivalent (SESE)
Regulation Medical Specialty
Radiology