-40%

Woodpecker I Sensor Style X-ray Sensor RVG Image System/Digital Machine Unit UPS

$ 279.83

Availability: 42 in stock
  • Condition: New
  • MPN: GJ1170100101
  • All returns accepted: Returns Accepted
  • Brand: Unbranded
  • Refund will be given as: Money Back
  • Return shipping will be paid by: Buyer
  • Intended Use/Discipline: Dental Laboratory
  • Restocking Fee: No
  • Item must be returned within: 30 Days
  • Country/Region of Manufacture: China

    Description

    STATEMENT :
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. So you can bid it on this item, only if you are an authorized purchaser. If the item is subject to FDA regulation, we have to verify your status as an authorized purchaser of this item before shipping of the item. Thanks for your understanding.
    BLX-5
    Features:
    1.) The tube voltage frequency of this machine is 30 KHz, and the tube current is 0.2 MA. The radiation scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead.
    2.) Toshiba 0.3mm x 0.3mm micro-focus tube.
    3.) No protective operation room is needed when installing the complete machine.
    4.) Flexible adjustment of position and angle of handpiece.
    5.) Compact in volume, light in weight, convenient for carrying.
    6.) Time is adjustable, high contrast of picture, imaging in focus.
    7.) There are vacuum components and high-pressure parts inside of the machine, so for your safety and the maintenance of the machine.
    8.) The tube head is equipped with excellent radiation-shield protection (except the radial mouth, and tests have shown that the radial index is zero. Safety is guaranteed.
    9.) Non-film inspection and storage can be realized when corresponding to a sensor.
    Specifications:
    Voltage: 110v±10% and 220V±10%
    Power: 24V 8000MA
    Charger: 220V/110V, 50Hz.
    Tube Current: 0.1mA
    Rating: 60W
    Frequency: 30 KHz
    Exposure Time: 1-9 seconds optional
    Leak Radiation: < 20μgy/h (12lb)
    Focus Skin Distance: >20cm
    Tube Voltage: 60KV
    Relative Humidity(RH) < 80%
    Storage Conditions: 5-40 degrees celsius, relative humidity.
    Net Weight: 5.5 kg
    Dimension: 47 * 42 * 19 cm
    Content:
    Main Unit x 1
    Dental Film Position x 1
    Charger x 1
    English Manual x 1
    Warranty Card x 1
    Operation of the Main Unit:
    1. Upon receiving, open the box and check the product for possible damage during shipping.
    2. Make sure the fittings on the encasement list are packaged within the box.
    BLX-5(8PLUS)
    Product introduction:
    This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz

    and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees

    located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
    Warning: After turning on the machine, wait for 1 minute, the voltage can be stabilized before normal use

    After each photo, you have to wait 30 seconds before you can take a normal photo
    TECHNICAL SPECIFICATIONS

    Tube Voltage    65kv
    Tube Current    1mA
    Time Exposure 0.1~~1.8s
    High pressure generator     30kHz DC
    Rated Power     60w
    Focal Spot To Skin Distance     >20CM
    Focus Spot Size      0.3mm(TOSHIBA)
    Charger Input Voltage  AC110V

    220V
    Supply Frequency  30Hz
    Radiation Leakage <20ugy/h
    Battery  24V DC 2600MA
    Weight 4.3KG
    Dimensions      37 cm×31 cm×28cm (L×W×H)
    Reference of the Angles

    '
    Tooth    Upper   Lower
    1-2 42   -15
    3     45   -18
    4-5 30   -10
    6-8 28   -5
    Reference of the time of exposure

    Tooth    Adult     Child
    Central & Lateral     0.2-0.3s
    0.2-0.3s
    Cuspid & 1st Bicuspid  0.3-0.4s
    0.3-0.4s
    Upper 5

    6 0.5-0.6s
    0.5-0.6s
    Upper 7

    8 1.3-1.8 s
    1.2-1.5.s
    Lower 5

    6 0.5-0.6s
    0.4-0.5 s
    Lower 7

    8 0.6-0.8 s
    0.5-0.7 s
    Packing List:
    Main machine   1pcs
    Power line      1pcs
    User manual     1pcs
    Operation of the Main Unit :
    Upon receiving

    open the box and check the product for possible damage during shipping.
    Make sure the fittings on the encasement list are packaged within the box.                          Turn on the Power

    the pilot lamp will be light up.During this time

    the digital tube  will show the fore setting time. Now the equipment is in standby mode.
    Setting the time (Skip to next step if unneeded) "+"

    and" -" buttons to reset the time as follows: press SET

    the pilot lamp above is illuminated

    the machine is now in the time setting mode→then press "+" and" -" to set the time needed (time range is 0.1-1.8seconds); The equipment is now in standby mode.
    Put the Tooth film plumb behind the tooth which is going to be taken picture

    and be as close as possible (the smooth side stick to the tooth)
    Keep the ball head plumb to the tooth projection position; Have the ball head

    tooth

    and tooth film steadily mutually plumb.
    After positioning

    use the ON/OFF on the main Unit

    to take pictures. (Notice: gently press 0.5 sec to turn it on)
    Points for Attention

    Make sure the angle of film

    tooth

    and ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.
    Remember to turn the power 0ff when work is done.
    Charge the battery if the machine cannot work and the red lamp lignt
    After turning the power on

    wait one minute before taking pictures

    this allows the ray to provide a steady output.
    The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs

    it will not be able to carry out the normal work of filming.
    When taking pictures

    the ON/OFF button could stop the objection and then the machine goes back to the preparation mode.
    Use high quality tooth film and developing liquid to make clear pictures.
    Handle the ball head gently while in use

    so as not to damage the delicate component.
    If a situation occurs

    preventing the machine from taking regular pictures

    contact the seller to solve the problem instead of trying to service the product yourself.
    Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.
    Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
    Other requests accordance with the scope of the technical parameters.
    Please read the manual carefully before using.
    LK-C27
    Fetures:
    1.This portable dental X-ray unit is high frequency machine.
    2.The body is small, light weight and nearly no radiation.
    3.It has excellent image quality, portable storage, save more space.
    4.It uses high frequency and DC international power supply.
    5.All of the components installed in the central PC board concentrated. Shock,set-up, electron tubes, all of them are insulation vacuum, sealed stereotype protection.
    6.There are also manual buttons installed on the surface of shell, as well as batteries and charges7.This unit mainly suitable for oral pre-treatment for learning internal organizational structure, root depth and so on, is indispensable in daily life clinic equipment, especially for dental implant surgery.
    8. It also can connect with sensor, is great convenience.
    9. The battery is durable, it can take about 5 hundred images after fully charged.
    10. It can be connected with intra-oral digital X-ray imaging system.
    Warning: After turning on the machine, wait for 1 minute, the voltage can be stabilized before normal use

    After each photo taking, you need to wait for the normal value to return before taking a normal photo.
    Technical Parameter:
    Tube voltage: 60KV
    Tube current: 1mA
    Exposure time: 0.1--2.0s
    Frequency: 30KHz
    Rate power: 60VA
    Distance from skin to cone: 130mm
    Tube focus: 0.3mm*0.3mm
    Battery: DC14.8V 6400mAh
    Charger input voltage: AC100V-240V±10%
    Output voltage: DC16.8V
    Ambient temperature: 5℃~40℃
    Relative temperature: <75%RH
    Net weight: 2.5KG
    Gross weight: 3.5KG
    Size(mm): 138*165*185
    Package size(mm): 220*240*275
    Packing List:
    Main body 1pc
    Charger 1pc
    User manual 1pc
    VXS2121
    Features

    The product is mainly composed of a sensor, an adaptor, a USB connection cable and workstation software. Working together with an X-ray equipment, the Product is intended to make X-ray radiography in dental clinics or veterinary clinics

    Sensor size Suitable for child

    adult single tooth

    and pets.
    Hardware Requirements

    Central Processor: Intel Core i3 or higher
    Internal Memory: 4GB or higher
    Hard Disk: 80GB or higher
    Display: 1280X1024
    USB interface: two
    Keyboard: One
    Mouse: One
    Software Requirement
    Operating Software

    Windows 7 SP1,8,10 32/64bit
    Runtime: .Net Framework 4.6 or higher, VC++ 2015
    Specification

    Product Name: Image RVG x-ray Sensor
    Product Model

    XVS2121
    Operating Voltage:5VDC
    Input power

    500mW
    Spatial Resolution

    ≥7Lp/mm
    Low contrast resolution

    Able to display holes with 1mm, 1.5mm, 2mm and
    2.5mm diameter on the 0.5mm-thick aluminium foil
    Image uniformity ≤2%
    Effective image area

    20.16*20.16mm
    Sensor Size

    26.5mm×32mm×11.7mm
    Adaptor Size

    60mm×40mm×29.2mm
    Total Cable Length: 3 m (sensor cable + control box cable to PC)
    Warranty:1 Year
    Accessory :
    Digital sensor: 1 Set
    USB cable :1 PCS
    U Disk: 1PCS
    Disposable protective sheath: 1 Box

    500

    silicon loop: 1 PCS
    Sensor holder: 1 PCS
    Aluminum plate:1 PCS (40*40*6mm)
    FDA Statement
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
    Seller name:Dentistryshop
    City,State:SHENZHEN,China
    Telephone number:0755-23998164
    Device Classification Name      System, X-Ray, Mobile
    510(K) Number K200976
    Device Name    SR-8230, SR-8230S Portable X-Ray Unit
    Regulation Number       892.172
    Classification Product Code      IZL
    Date Received  4/13/2020
    Decision Date   6/10/2020
    Decision     Substantially Equivalent (SESE)
    Regulation Medical Specialty    Radiology