【USA】Dental Portable Digital X-Ray Imaging SystemBLX-5(8PLUS) + Head Light

$ 422.39

Availability: 14 in stock

Description

Product Introduction:
This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz

and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees

located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
Warning:
After turning on the machine, wait for 1 minute, the voltage can be stabilized before normal use

After each photo, you have to wait 30 seconds before you can take a normal photo
TECHNICAL SPECIFICATIONS

Tube Voltage
60kV
Tube Current
1mA
Time Exposure
1~~9s
High pressure generator
30kHz DC
Rated Power
60w
Focal Spot To Skin Distance
>20CM
Focus Spot Size
0.3mm(TOSHIBA)
Charger Input Voltage
AC110V

220V
Supply Frequency
50Hz±1%
Radiation Leakage
<20ugy/h
Battery
24V DC 8000MA
Weight
2KG
Dimensions
25 cm×11..5 cm×17cm (L×W×H)
Reference of the Angles

'
Tooth
Upper
Lower
1-2
42
-15
3
45
-18
4-5
30
-10
6-8
28
-5
Reference of the time of exposure

Tooth
Adult
Child
Central & Lateral
0.8-1.2
0.8-1.0
Cuspid & 1st Bicuspid
1.2-1.4
1.0- 1.2
Upper 5

6
1.6-1.8
1.4-1.6
Upper 7

8
3.0-3.5
2.8-3.3.
Lower 5

6
1.8-2.0.
1.6-1.8
Lower 7

8
2.0-2.5
1.8-2.3
Packing List:
Main machine   1pc
Power line      1pc
User manual     1pc
Operation of the Main Unit :
Upon receiving

open the box and check the product for possible damage during shipping.
Make sure the fittings on the encasement list are packaged within the box.
Install the blue ray tube to the foreside of the ball head

then tighten it.
Turn on the Power

the pilot lamp will be light up.During this time

the digital tube  will show the fore setting time. Now the equipment is in standby mode.
Setting the time (Skip to next step if unneeded) Use the "SET"

"+"

and" -" buttons to reset the time as follows: press SET

the pilot lamp above is illuminated

the machine is now in the time setting mode

then press "+" and" -" to set the time needed (time range is 1-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode.
Put the Tooth film plumb behind the tooth which is going to be taken picture

and be as close as possible (the smooth side stick to the tooth)
Keep the ball head plumb to the tooth projection position; Have the ball head

tooth

and tooth film steadily mutually plumb.
After positioning

use the ON/OFF on the main Unit

to take pictures. (Notice: gently press 0.5 sec to turn it on)
After exposure to the tube

press the start button again  in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray

so the dental films can be used again)
Repeat step 6 to reset the picturing time.To repeat the picturing process

please repeat steps 7 to 9.
Turn the power  off when the work is finished

press POWER

making sure the pilot lamp is off.Don't keep the machine long in standby mode.
Points for Attention
:
Make sure the angle of film

tooth

and ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.
Remember to turn the power 0ff when work is done.
Charge the battery if the machine cannot work and the red lamp lignt
After turning the power on

wait one minute before taking pictures

this allows the ray to provide a steady output.
The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs

it will not be able to carry out the normal work of filming.
When taking pictures

the ON/OFF button could stop the objection and then the machine goes back to the preparation mode.
Use high quality tooth film and developing liquid to make clear pictures.
Handle the ball head gently while in use

so as not to damage the delicate component.
We usually set the time between 3-8 seconds when taking pictures

but the actual time of ray output is 0.2-0.5 seconds.
If a situation occurs

preventing the machine from taking regular pictures

contact the seller to solve the problem instead of trying to service the product yourself.
Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.
Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
Other requests accordance with the scope of the technical parameters.
Please read the manual carefully before using
Applied for traditional or smaller dental films and wireless imaging plates (digital sensor).
During taking picture, it’s better to put the film in the exactly position for making the ill tooth image displayed in the middle of the film.
Reduces Patient's Oral Discomfort and Allows for Better Accuracy and Ease of X-ray Taking Procedure.
Specifications:
Material: Plastics
Excellent Sensor Protection
Dental X-ray sensor positioner
For digital sensor with line
The clamp size can be adjusted for different imaging plates
Satisfaction Guaranteed!
Package:
1, (Green) for right maxillary upper premolar/molar and left mandibular
2, (Blue) for left maxillary premolar and right mandibular premolar/molar
3, (Yellow) for maxillary/ mandbular incisor -Anterior teeth
4.( 2 pcs small green accessories) Special for smaller sensor, like the introduction book show.
One suit includes 3 pcs

Left, Right, Upper

FDA Statement
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
Seller name:Dentistryshop
City,State:SHENZHEN,China
Telephone number:0755-23998164
Feedback
We commited ourselfs to your 100% satisfaction both with our goods and services.
• Please leave me FIVE star POSITIVE feedback if you are satisfied with our items.
• Please message me immediately before leave us neutral feedback or negtive feedback, We will try our best to resolve any problem for you untill you are satisfied.
Payment
We accept PayPal and bank wire transfer. All payments must be made within 7 days after the auction ends. Non-paying bidders will be reported to eBay. Please don't buy an item if you can't/won't pay for it.
Paypal is the easiest way to pay for items on eBay. Please make sure your Paypal and eBay accounts have the same physical address used for delivery and the same e-mail address to ensure payment confirmation.
Shipping: Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility.
Shipping
The goods you odered will be posted out in the second working day after the paymet has been made. (We will inform you via email if any delay occured due to holiday events.
General shipping time is between 7-12 working days. (After the shipping started, the order will be monitored and the track of the item will be posted on paypal)
Returns
If the item you received is damaged or defective,Please Leave message immidately.We will free exchange or refund.
We will pay the return shipping costs if the product is defective or the return is a result of our error. If the item is returned for any other reason you are responsible for the return shipping charges.
You can return your purchase for up to 15 days from the date of delivery. No refund will be issued if the product shows signs of use. Returned package must be in the original packaging, everything must be in new condition, No missing parts.
Our guarantee does not cover accidental damage or wear of product caused by customer.Thank you very much for your understanding!
Leave message
If you have any questions, please Leave message via ebay message system, or send E-mail: dental7(at)baistra.com to me!
We're one of the largest online dental suppliers based on many qualified manufacturers in china.
If you Leave message immediately after placing the order, we will make every effort to assist you with your change request. Unfortunately, we can not make changes or cancel an order once it has shipped.
Any help,need or questions, please do not hesitate to Leave message. Looking forward to our friendly & win-win cooperation!
Device Classification Name      System, X-Ray, Mobile
510(K) Number K200976
Device Name    SR-8230, SR-8230S Portable X-Ray Unit
Regulation Number       892.172
Classification Product Code      IZL
Date Received  4/13/2020
Decision Date   6/10/2020
Decision     Substantially Equivalent (SESE)
Regulation Medical Specialty    Radiology